6.36
GSD 41 Data Concentrator
Removal:
1. Gain access to the avionics shelf in the tail area.
2. Unlock the unit from the rack by loosening the ratcheting latch mechanism.
3. Remove the unit from the rack.
Reinstallation:
1. Visually inspect the connectors to ensure there are no bent or damaged pins. Repair any damage.
2. Insert the unit into the installation rack.
Do not use excessive force when inserting the GSD 41 into the rack.
This may cause damage to occur to the connectors, unit, and/or
unit rack. If heavy resistance is felt during installation, stop!
Remove the GSD 41 and identify the source of resistance.
3. Lock the unit into the rack by using the ratcheting latch mechanism.
4. Configure the GSD 41 according to Section 3.26.
G1000 / GFC 700 System Maintenance Manual - 300/B300 Series King Air
190-00716-01
CAUTION:
Page 6-15
Revision 1