Genie S-40 Operator's Manual page 31

Boom lift
Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Eight Edition • First Printing
At the Ground Controls
1
Select a test area that is firm, level and free of
obstruction.
2
Turn the key switch to ground control.
3
Pull out the red Emergency Stop button to the
on position.
Result: The beacons (if equipped) should
flash.
4
Start the engine. See Operating Instructions
section.
Test Emergency Stop
5
Push in the red Emergency Stop button to the
off position.
Result: The engine should shut off and no
functions should operate.
6
Pull out the red Emergency Stop button to the
on position and restart the engine.
Test Machine Functions
7
Do not hold the function enable
switch to either side. Attempt to
activate each boom and platform
function toggle switch.
Result: No boom and platform functions should
operate.
8
Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent
alarm (if equipped) should sound while the
boom is lowering.
Part No. 1259838
Test the Tilt Sensor
9
Pull out the platform red Emergency Stop
button to the on position. Turn the key switch
to platform control.
10 Open the tank side turntable
cover and locate the tilt
sensor next to the control
box.
11 Press down one side of the
tilt sensor.
Result: The alarm, located in the platform,
should sound.
Test Emergency Controls
12 Turn the key switch to ground control and shut
the engine off.
13 Pull out the red Emergency Stop button to the
on position.
14 Simultaneously hold the emergency
power switch on and activate each
boom function toggle switch.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
S-40 • S-45