Applicable Materials; Flue Pipe Position - Daikin CHYHBH05AA Installer's Reference Manual

Hybrid for multi heat pump – heat pump module
Hide thumbs Also See for CHYHBH05AA:
Table of Contents

Advertisement

7 Installation
Number of
Concentric
units
Gas
Air intake
exhaust
6
206
7
217
8
229
9
240
10
251
11
263
12
274
13
286
14
297
15
308
16
320
17
331
18
342
19
354
20
365
Special remark regarding C
93
the chimney have to be 200×200 mm.
INFORMATION
In case of a C
type flue gas system, a flue gas flap valve
13
(EKFGF1A) is recommended.
7.12.5

Applicable materials

Materials for the installation of the gas exhaust and/or air intake
MUST be bought according to the table below.
D BG BA
IT
HR HU SK
CZ
SI
ES PT PL GR CY IE TR
C
13
C
33
C
43
C
53
C
(a)
63
C
83
C
93
(a)
Gas exhaust/air intake parts can be bought from the 3
party. All parts purchased from an external supplier MUST
comply with EN14471.
(b)
NOT allowed.
7.12.6

Flue pipe position

See the local and national regulations.
Especially for UK:
Only use flue products approved by the boiler manufacturer, which
can be bought from the supplier of your boiler.
Refer to the field supplied accessories for all available accessories.
Installer reference guide
42
Dual pipe
Gas
Air intake
exhaust
386
206
326
407
217
344
429
229
363
449
240
380
470
251
398
493
263
416
513
274
434
536
286
453
556
297
470
577
308
488
599
320
507
620
331
524
641
342
541
663
354
560
683
365
578
: The minimum inner dimensions of
CH AT
MT LT
LT LV UK FR
Daikin
Daikin
Daikin
Daikin
(b) (a)
(b)
(a)
Daikin
Daikin
rd
Q
R
D
N
E
B
Terminal position
A
Directly below an open able window or
other opening (e.g. air brick)
(b)
B
Below gutters, soil pipes or drain pipes
C
Below eaves
D
Below balconies or car front roofs
E
From vertical drain pipes and soil pipe
F
From internal or external corners
G
Above ground, roof or balcony level
H
From a surface facing a terminal
I
From a terminal discharging towards
another terminal
J
From an opening in a car port (e.g.
door, window) into a dwelling
K
Vertically from a terminal on the same
wall
L
Horizontally from a terminal on the
same wall
M
Above an opening, air brick, opening
windows, etc.
N
Horizontally to an opening, air brick,
opening windows, etc.
P
Above roof level (to base terminal)
Q
From an adjacent wall to flue
R
From an adjacent opening window
Daikin hybrid for multi heat pump – heat pump module
S
P
A
C
B
M
N
Q
Q
A
P
G
J
T2
T2
T2
T
T1
F
F
H
I
K
L
Minimum
distance (mm)
CHYHBH05+08AA + EHYKOMB33A
4P471761-1A – 2017.10
300
75
200
150
300
600
1200
1500
300
1000