Field settings table
Breadcrumb
Field code
Setting name
A.8
[5-03]
--
A.8
[5-04]
--
A.8
[5-05]
--
A.8
[5-06]
--
A.8
[5-07]
--
A.8
[5-08]
--
A.8
[5-09]
--
A.8
[5-0A]
--
A.8
[5-0B]
--
A.8
[5-0C]
--
A.8
[5-0D]
--
A.8
[5-0E]
--
A.8
[6-00]
The temperature difference determining the heat pump ON temperature.
A.8
[6-01]
The temperature difference determining the heat pump OFF temperature.
A.8
[6-02]
--
A.8
[6-03]
--
A.8
[6-04]
--
--
A.8
[6-05]
A.8
[6-06]
--
A.8
[6-07]
--
A.8
[6-08]
What is the hysteresis to be used in reheat mode?
A.8
[6-09]
--
A.8
[6-0A]
What is the desired comfort storage temperature?
A.8
[6-0B]
What is the desired eco storage temperature?
A.8
[6-0C]
What is the desired reheat temperature?
A.8
[6-0D]
What is the desired DHW production type?
A.8
[6-0E]
What is the maximum temperature setpoint?
A.8
[7-00]
--
A.8
[7-01]
--
A.8
[7-02]
How many leaving water temperature zones are there?
A.8
[7-03]
PE factor
A.8
[7-04]
Savings mode
A.8
[7-05]
--
A.8
[8-00]
--
A.8
[8-01]
Maximum running time for domestic hot water operation.
A.8
[8-02]
Anti-recycling time.
A.8
[8-03]
--
A.8
[8-04]
--
A.8
[8-05]
Allow modulation of the LWT to control the room temp?
A.8
[8-06]
Leaving water temperature maximum modulation.
A.8
[8-07]
--
A.8
[8-08]
--
A.8
[8-09]
What is the desired comfort main LWT in heating?
A.8
[8-0A]
What is the desired eco main LWT in heating?
A.8
[8-0B]
Target flow rate during HP mode
A.8
[8-0C]
Target flow rate during hybrid mode
A.8
[8-0D]
Target flow rate during boiler mode
A.8
[9-00]
What is the maximum desired LWT for main zone in heating?
A.8
[9-01]
What is the minimum desired LWT for main zone in heating?
A.8
[9-02]
--
A.8
[9-03]
--
A.8
[9-04]
--
A.8
[9-05]
What is the minimum desired LWT for add. zone in heating?
A.8
[9-06]
What is the maximum desired LWT for add. zone in heating?
A.8
[9-07]
--
A.8
[9-08]
--
A.8
[9-09]
--
A.8
[9-0A]
--
A.8
[9-0B]
What emitter type is connected to the main LWT zone?
A.8
[9-0C]
Room temperature hysteresis.
A.8
[9-0D]
Pump speed limitation
A.8
[9-0E]
--
A.8
[A-00]
--
A.8
[A-01]
--
A.8
[A-02]
--
A.8
[A-03]
--
A.8
[A-04]
--
A.8
[B-00]
--
A.8
[B-01]
--
A.8
[B-02]
--
A.8
[B-03]
--
CHYHBH*
Range, step
Default value
0
10
50
50
50
50
20
20
20
20
1
0
R/W
2~20°C, step: 1°C
2°C
R/W
0~10°C, step: 1°C
2°C
0
0
0
0
0
0
R/W
2~20°C, step: 1°C
5°C
0
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
[E-06]=1
[E-07] ≠
40~75°C, step: 1°C, 75°C
6:
[E-07] = 6: 40~60°C, step: 1°C, 60°C
[E-06]=0
40~65°C, step: 1°C, 65°C
0
2
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0~6, step: 0,1
2,5
R/W
0: Economical
1: Ecological
0
1
R/W
5~95 min, step: 5 min
30 min
R/W
0~10 hour, step: 0,5 hour
1,5 hour
50
0
R/W
0: No
1: Yes
R/W
0~10°C, step: 1°C
5°C
18
20
R/W
[9-01]~[9-00]°C, step: 1°C
45°C
R/W
[9-01]~[9-00]°C, step: 1°C
40°C
R/W
10~20, step: 0,5
CHYHBH05: 13
CHYHBH08: 15
R/W
10~20, step: 0,5
CHYHBH05: 13
CHYHBH08: 15
R/W
10~20, step: 0,5
16
R/W
37~80°C, step: 1°C
80°C
R/W
15~37°C, step: 1°C
25°C
22
5
1
R/W
15~37°C, step: 1°C
25°C
R/W
37~80°C, step: 1°C
80°C
5
22
5
5
R/W
0: Quick
1: Slow
R/W
1~6°C, step: 0,5°C
1 °C
R/W
0~8,step:1
6
0~8,step:1
6
0
0
0
0
0
0
0
0
0
5/6
Installer setting at variance with
default value
Date
Value
4P471775-1 - 2016.12