Identification Label: Gas Boiler; Combining Units And Options; Possible Options For The Indoor Unit - Daikin CHYHBH05AA Installer's Reference Manual

Hybrid for multi heat pump – heat pump module
Hide thumbs Also See for CHYHBH05AA:
Table of Contents

Advertisement

Code
HY
Hybrid indoor unit
HBH
Hydrobox heating only
05
Capacity class
AA
Model series
V3
Power supply
5.2.2

Identification label: gas boiler

Location
Model identification
b
No:
c
Anno:
Condensing boiler
d
Type:
e
NOx classe:
f
PIN:
r
G.C.:
s
SVGW:
h
g
k
Qnw(net)
l
PMW
m
Qn (net)
n
Pn
o
PMS
p
Tmax
q
a
Model
b
Serial number
c
Production year
d
Appliance type
e
NOx class
f
PIN number: notified body reference
g
Destination country
h
Gas type
i
Gas supply pressure (mbar)
j
Appliance category
k
Domestic hot water heat output (kW)
l
Maximum domestic hot water pressure (bar)
m
Heat output (space heating) (kW)
n
Nominal power (kW)
CHYHBH05+08AA + EHYKOMB33A
Daikin hybrid for multi heat pump – heat pump module
4P471761-1A – 2017.10
Description
a
i
j
kW
bar
kW
kW
bar
°C
0063
2013
5 About the units and options
o
Maximum space heating pressure (bar)
p
Maximum flow temperature (°C)
q
Electrical supply
r
GCN gas council number
s
SVGW number
5.3

Combining units and options

5.3.1

Possible options for the indoor unit

User interface (EKRUCBL*)
The user interface and a possible additional user interface are
available as an option.
The additional user interface can be connected:
▪ To have both:
▪ control close to the indoor unit,
▪ room thermostat functionality in the principal space to be
heated.
▪ To have an interface containing other languages.
Following user interfaces are available:
▪ EKRUCBL1 contains following languages: German, French,
Dutch, Italian.
▪ EKRUCBL2 contains following languages: English, Swedish,
Norwegian, Finnish.
▪ EKRUCBL3 contains following languages: English, Spanish,
Greek, Portuguese.
▪ EKRUCBL4 contains following languages: English, Turkish,
Polish, Romanian.
▪ EKRUCBL5 contains following languages: German, Czech,
Slovenian, Slovakian.
▪ EKRUCBL6 contains following languages: English, Croatian,
Hungarian, Estonian.
▪ EKRUCBL7 contains following languages: English, German,
Russian, Danish.
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see
interface" on
page 36.
Simplified user interface (EKRUCBS)
▪ The simplified user interface can only be used in combination with
the main user interface.
▪ The simplified user interface acts as room thermostat and needs
to be installed in the room that you want it to control.
For installation instructions, see the installation and operation
manual of the simplified user interface.
Room thermostat (EKRTWA, EKRTR1, RTRNETA)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1 and
RTRNETA). Thermostat RTRNETA can only be used in heating-only
systems.
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Digital I/O PCB (EKRP1HB)
The digital I/O PCB is required to provide the following signals:
▪ Alarm output
"7.10.8  To connect the user
Installer reference guide
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehykomb33aChyhbh08aa

Table of Contents