Applicable Materials; Ejha04Aav3 + Nhy2Komb28+32Aa; Daikin Altherma H Hybrid; Flue Pipe Position - Daikin INTERGAS Altherma NHY2KOMB28AA Installer's Reference Manual

Hide thumbs Also See for INTERGAS Altherma NHY2KOMB28AA:
Table of Contents

Advertisement

Number of
Concentric
units
Gas
Air intake
exhaust
3
166
4
176
5
186
6
196
7
206
8
216
9
226
10
236
11
247
12
257
13
267
14
277
15
287
16
297
17
307
18
317
19
328
20
338
Special remark regarding C
93
the chimney have to be 200×200 mm.
9.9.5

Applicable materials

Materials for the installation of the gas exhaust and/or air intake
MUST be bought according to the table below.
D BG BA
IT
HR HU SK
CZ
SI
ES PT PL GR CY IE TR
C
13
C
33
C
43
C
53
C
(a)
63
C
83
C
93
(a)
Gas exhaust/air intake parts can be bought from the 3
party. All parts purchased from an external supplier MUST
comply with EN14471.
(b)
NOT allowed.
9.9.6

Flue pipe position

See the local and national regulations.
Especially for UK:
Only use flue products approved by the boiler manufacturer, which
can be bought from the supplier of your boiler.
See
"6.3 Combining units and options" on

EJHA04AAV3 + NHY2KOMB28+32AA

Daikin Altherma H Hybrid

4P556861-1A – 2019.05
Dual pipe
Gas
Air intake
exhaust
311
166
263
330
176
279
349
186
295
367
196
311
386
206
326
404
216
342
423
226
358
442
236
374
463
247
391
482
257
407
500
267
423
519
277
439
538
287
454
556
297
470
575
307
486
594
317
502
614
328
519
633
338
535
: The minimum inner dimensions of
CH AT
MT LT
LT LV UK FR
Daikin
Daikin
Daikin
Daikin
(b) (a)
(b)
(a)
Daikin
Daikin
rd
page 13.
Q
R
D
N
E
B
Terminal position
A
Directly below an open able window or
other opening (e.g. air brick)
(b)
B
Below gutters, soil pipes or drain pipes
C
Below eaves
D
Below balconies or car front roofs
E
From vertical drain pipes and soil pipe
F
From internal or external corners
G
Above ground, roof or balcony level
H
From a surface facing a terminal
I
From a terminal discharging towards
another terminal
J
From an opening in a car port (e.g.
door, window) into a dwelling
K
Vertically from a terminal on the same
wall
L
Horizontally from a terminal on the
same wall
M
Above an opening, air brick, opening
windows, etc.
N
Horizontally to an opening, air brick,
opening windows, etc.
P
Above roof level (to base terminal)
Q
From an adjacent wall to flue
R
From an adjacent opening window
9 Installation
S
P
A
C
B
M
N
Q
Q
A
P
G
J
T2
T2
T2
T
T1
F
F
H
I
K
L
Minimum
distance (mm)
Installer reference guide
300
75
200
150
300
600
1200
1500
300
1000
51

Advertisement

Table of Contents
loading

Table of Contents