Daikin CHYHBH05AA Installer's Reference Manual page 104

Hybrid for multi heat pump – heat pump module
Hide thumbs Also See for CHYHBH05AA:
Table of Contents

Advertisement

4/6
Field settings table
Breadcrumb
Field code
Setting name
A.6.7
[7-04]
└─ Emergency
A.6.C
└─ Overview settings
A.8
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
A.8
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
A.8
[0-02]
High ambient temp. for LWT add zone heating WD curve.
A.8
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
A.8
[0-04]
--
A.8
[0-05]
--
A.8
[0-06]
--
A.8
[0-07]
--
A.8
[0-0B]
Leaving water value for high ambient temp. for DHW WD curve.
A.8
[0-0C]
Leaving water value for low ambient temp. for DHW WD curve.
A.8
[0-0D]
High ambient temp. for DHW WD curve.
A.8
[0-0E]
Low ambient temp. for DHW WD curve.
A.8
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
A.8
[1-01]
High ambient temp. for LWT main zone heating WD curve.
A.8
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
A.8
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
A.8
[1-04]
--
A.8
[1-05]
--
A.8
[1-06]
--
A.8
[1-07]
--
A.8
[1-08]
--
A.8
[1-09]
--
A.8
[1-0A]
What is the averaging time for the outdoor temp?
A.8
[2-00]
When should the disinfection function be executed?
A.8
[2-01]
Should the disinfection function be executed?
A.8
[2-02]
When should the disinfection function start?
A.8
[2-03]
What is the disinfection target temperature?
A.8
[2-04]
How long must the tank temperature be maintained?
A.8
[2-05]
Room antifrost temperature
A.8
[2-06]
Room frost protection
A.8
[2-09]
Adjust the offset on the measured room temperature
A.8
[2-0A]
Adjust the offset on the measured room temperature
A.8
[2-0B]
What is the required offset on the measured outdoor temp.?
A.8
[3-00]
Is auto restart of the unit allowed?
A.8
[3-01]
--
A.8
[3-02]
--
A.8
[3-03]
--
A.8
[3-04]
--
A.8
[3-05]
--
A.8
[3-06]
What is the maximum desired room temperature in heating?
A.8
[3-07]
What is the minimum desired room temperature in heating?
A.8
[3-08]
--
A.8
[3-09]
--
A.8
[4-00]
--
A.8
[4-01]
--
A.8
[4-02]
Below which outdoor temperature is heating allowed?
A.8
[4-03]
--
A.8
[4-04]
--
A.8
[4-05]
--
A.8
[4-06]
-- (Do not change this value)
A.8
[4-07]
--
A.8
[4-08]
--
A.8
[4-09]
--
A.8
[4-0A]
--
A.8
[4-0B]
--
A.8
[4-0C]
--
A.8
[4-0D]
--
A.8
[4-0E]
Is the installer on site?
A.8
[5-00]
--
A.8
[5-01]
What is the equilibrium temperature for the building?
A.8
[5-02]
--
4P471775-1 - 2016.12
Range, step
Default value
R/W
0: Economical
1: Ecological
R/W
0: Manual
1: Automatic
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
[9-05]~[9-06]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
8
12
35
20
R/W
35~[6-0E]°C, step: 1°C
55°C
R/W
45~[6-0E]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00]°C, step: 1°C
60°C
R/W
[9-01]~min(45,[9-00])°C, step: 1°C
35°C
1
1
20
35
22
18
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0: No
1: Yes
R/W
0~23 hour, step: 1 hour
23
R/W
fixed value
60°C
R/W
40~60 min, step: 5 min
40 min
R/W
4~16°C, step: 1°C
8°C
R/W
0: Disabled
1: Enabled
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: A.3.2.4
30°C
R/W
12~18°C, step: A.3.2.4
12°C
35
15
1
0
R/W
14~35°C, step: 1°C
25°C
3
1
0
0/1
1
0
1
0
1
35
3
R/W
0: No
1: Yes
0
R/W
-15~35°C, step: 1°C
5°C
0
Installer setting at variance with
default value
Date
Value
CHYHBH*