Table 2 – Minimum Floor Area: Indoor Unit - Daikin CHYHBH05AA Installer's Reference Manual

Hybrid for multi heat pump – heat pump module
Hide thumbs Also See for CHYHBH05AA:
Table of Contents

Advertisement

15 Technical data
15.5
Table 2 – Minimum floor area: indoor unit
dm (kg)
H=500 mm,
H=800 mm
H=900 mm
600 mm,
700 mm
h=600 mm
h=700 mm
h=800 mm
0.10
0.73
0.62
0.20
1.45
1.24
0.30
2.18
1.87
0.40
2.90
2.49
0.50
3.63
3.11
0.60
4.36
3.73
0.70
5.08
4.36
0.80
5.81
4.98
0.90
6.95
5.60
1.00
8.58
6.30
1.10
10.38
7.63
1.20
12.36
9.08
1.30
14.50
10.65
1.40
16.82
12.36
1.50
19.31
14.18
1.60
21.97
16.14
1.70
24.80
18.22
1.80
27.80
20.43
1.90
30.98
22.76
2.00
34.32
25.22
2.10
37.84
27.80
2.20
41.53
30.51
2.30
45.39
33.35
2.40
49.42
36.31
2.50
53.63
39.40
2.6
58.00
42.62
2.7
62.55
45.96
2.8
67.27
49.42
2.9
72.16
53.02
3
77.22
56.74
3.1
82.46
60.58
3.2
87.86
64.55
3.3
93.44
68.65
10
350
(mm)
Installer reference guide
92
H=1000 mm
H=1100 mm
H=1200 mm
h=900 mm
h=1000 mm
h=1100 mm
0.54
0.48
0.44
1.09
0.97
0.87
1.63
1.45
1.31
2.18
1.94
1.74
2.72
2.42
2.18
3.27
2.90
2.61
3.81
3.39
3.05
4.36
3.87
3.49
4.90
4.36
3.92
5.45
4.84
4.36
5.99
5.33
4.79
6.95
5.81
5.23
8.16
6.44
5.66
9.46
7.47
6.10
10.86
8.58
6.95
12.36
9.76
7.91
13.95
11.02
8.93
15.64
12.36
10.01
17.42
13.77
11.15
19.31
15.25
12.36
21.29
16.82
13.62
23.36
18.46
14.95
25.53
20.17
16.34
27.80
21.97
17.79
30.17
23.83
19.31
32.63
25.78
20.88
35.19
27.80
22.52
37.84
29.90
24.22
40.59
32.07
25.98
43.44
34.32
27.80
46.38
36.65
29.69
49.42
39.05
31.63
52.56
41.53
33.64
500
Minimum floor area (m²)
H=1300 mm
H=1400 mm
h=1200 mm
h=1300 mm
0.40
0.36
0.34
0.79
0.73
0.67
1.19
1.09
1.01
1.58
1.45
1.34
1.98
1.82
1.68
2.38
2.18
2.01
2.77
2.54
2.35
3.17
2.90
2.68
3.57
3.27
3.02
3.96
3.63
3.35
4.36
3.99
3.69
4.75
4.36
4.02
5.15
4.72
4.36
5.55
5.08
4.69
5.94
5.45
5.03
6.54
5.81
5.36
7.38
6.20
5.70
8.27
6.95
6.03
9.22
7.74
6.60
10.21
8.58
7.31
11.26
9.46
8.06
12.36
10.38
8.85
13.50
11.35
9.67
14.70
12.36
10.53
15.96
13.41
11.42
17.26
14.50
12.36
18.61
15.64
13.32
20.01
16.82
14.33
21.47
18.04
15.37
22.98
19.31
16.45
24.53
20.61
17.57
26.14
21.97
18.72
27.80
23.36
19.90
INFORMATION
▪ h=The height measured from the floor to the flare nut.
▪ H=The height measured from the floor to the bottom of
the casing.
▪ For intermediate H values (i.e., when H is between 2 H
values from the table), consider the value that
corresponds to the lower H value from the table. If
H=950  mm, consider the value that corresponds to
"H=900 mm".
▪ In cases where H≤600  mm, h is always considered to
be 600  mm, as specified in IEC  60335-2-40:2013 A1
2016, clause GG2.
▪ For intermediate dm values (i.e., when dm is between 2
dm values from the table), consider the value that
corresponds to the higher dm value from the table. If
dm=1.55 kg, consider "dm=1.6 kg".
▪ Systems with a total refrigerant charge <1.225  kg are
NOT subjected to any requirements to the installation
room.
Daikin hybrid for multi heat pump – heat pump module
H=1500 mm
H=1600 mm
H=1700 mm
h=1400 mm
h=1500 mm
h=1600 mm
0.31
0.29
0.27
0.62
0.58
0.54
0.93
0.87
0.82
1.24
1.16
1.09
1.56
1.45
1.36
1.87
1.74
1.63
2.18
2.03
1.91
2.49
2.32
2.18
2.80
2.61
2.45
3.11
2.90
2.72
3.42
3.20
3.00
3.73
3.49
3.27
4.05
3.78
3.54
4.36
4.07
3.81
4.67
4.36
4.08
4.98
4.65
4.36
5.29
4.94
4.63
5.60
5.23
4.90
5.91
5.52
5.17
6.30
5.81
5.45
6.95
6.10
5.72
7.63
6.64
5.99
8.34
7.26
6.38
9.08
7.91
6.95
9.85
8.58
7.54
10.65
9.28
8.16
11.49
10.01
8.80
12.36
10.76
9.46
13.25
11.55
10.15
14.18
12.36
10.86
15.15
13.19
11.60
16.14
14.06
12.36
17.16
14.95
13.14
CHYHBH05+08AA + EHYKOMB33A
4P471761-1A – 2017.10
H=1800 mm
h=1700 mm
0.26
0.51
0.77
1.03
1.28
1.54
1.79
2.05
2.31
2.56
2.82
3.08
3.33
3.59
3.84
4.10
4.36
4.61
4.87
5.13
5.38
5.64
5.90
6.16
6.68
7.23
7.79
8.38
8.99
9.62
10.27
10.95
11.64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehykomb33aChyhbh08aa

Table of Contents