Field settings table
Breadcrumb
Field code
Setting name
User settings
└─ Preset values
└─ Room temperature
7.4.1.1
Comfort (heating)
7.4.1.2
Eco (heating)
└─ LWT main
7.4.2.1
[8-09]
Comfort (heating)
7.4.2.2
[8-0A]
Eco (heating)
7.4.2.5
Comfort (heating)
7.4.2.6
Eco (heating)
└─ Tank temperature
7.4.3.1
[6-0A]
Storage comfort
7.4.3.2
[6-0B]
Storage eco
7.4.3.3
[6-0C]
Reheat
└─ Electricity price
7.4.5.1
[C-0C]
High
[D-0C]
7.4.5.2
[C-0D]
Medium
[D-0D]
7.4.5.3
[C-0E]
Low
[D-0E]
└─ Fuel price
7.4.6
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
7.7.1.1
[1-01]
Set weather-dependent heating
7.7.1.1
[1-02]
Set weather-dependent heating
7.7.1.1
[1-03]
Set weather-dependent heating
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
7.7.2.1
[0-01]
Set weather-dependent heating
7.7.2.1
[0-02]
Set weather-dependent heating
7.7.2.1
[0-03]
Set weather-dependent heating
Installer settings
└─ System layout
└─ Standard
A.2.1.1
[E-00]
Unit type
A.2.1.2
[E-01]
Compressor type
A.2.1.3
[E-02]
Indoor software type
A.2.1.6
[D-01]
Forced off contact
A.2.1.7
[C-07]
Unit control method
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.2
[E-06]
DHW tank
A.2.2.3
[E-07]
DHW tank type
A.2.2.4
[C-05]
Contact type main
A.2.2.5
[C-06]
Contact type add.
A.2.2.6.2
[D-07]
Digital I/O PCB
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.A
[D-02]
DHW pump
4P471775-1 - 2016.12
Low ambient temp. for LWT main zone heating
WD curve.
High ambient temp. for LWT main zone heating
WD curve.
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating
WD curve.
Low ambient temp. for LWT add zone heating
WD curve.
Solar kit
Alarm output
Range, step
Default value
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
R/W
[9-01]~[9-00], step: 1°C
45°C
R/W
[9-01]~[9-00], step: 1°C
40°C
R/W
-10~10°C, step: 1°C
0°C
R/W
-10~10°C, step: 1°C
-2°C
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E]) °C, step: 1°C
50°C
R/W
30~min(50, [6-0E]) °C, step: 1°C
50°C
R/W
0,00~990/kWh
20/kWh
R/W
0,00~990/kWh
20/kWh
R/W
0,00~990/kWh
15/kWh
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00]°C, step: 1°C
60°C
R/W
[9-01]~min(45,[9-00])°C, step: 1°C
35°C
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
[9-05]~[9-06]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/O
0~5
3: Hybrid
R/O
0: 08
R/O
1: Type 2
R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/W
0: At unit
1: In room
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0~6
4: Type 5
6: Type 7
R/W
1: Thermo ON/OFF
2: C/H request
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0: No
1: Yes
R/W
0: Normally open
1: Normally closed
R/O
0: No
1: Pwr consmp ctrl
R/O
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
Installer setting at variance with