Status Byte Format - Epson FilmScan 200 Service Manual

Hide thumbs Also See for FilmScan 200:
Table of Contents

Advertisement

1.4.6

Status Byte Format

This section describes the status bytes format. The status indicates the current condition of the scanner
and image data.
Below describes details of the status byte.
Bit7:
Error flag. Set to "1" when a system error or operation error occurred
Bit6:
Frame end flag. Set to "1" when final Data-Block of each frame.
Bit5:
Area end flag. Set to "1" when final Data-Block of last frame.
Bit4..
Option Flag. When a option equipment is installed, set to "1".
Bit3:
Color attribute 1. See table below.
Bit2:
Color attribute 2. See table below.
Bit1:
(reserved) Always "0".
Bit0
(reserved) Always "0".
Monochrome Mode [ESC C 0]
Line mode
Byte Mode
Rev. A
Figure 1-18. Status Byte
Table 1-7. Color Attribute
Bit
Line Transfer
Byte Transfer
3
0
Green
0
Red
1
Blue
1
GRB
0
RGB
1
GRB
0
RGB
1
GENERAL DESCRIPTION
2
0
1
0
1
1
0
1
0
1-