Electrical Specifications; Safety And Emc; Resistance To Electric Noise; Environmental Conditions - Epson FilmScan 200 Service Manual

Hide thumbs Also See for FilmScan 200:
Table of Contents

Advertisement

1.2.3 Electrical Specifications


Rated Voltage:

Input voltage:

Rated frequency range:

Input frequency range:

Power consumption:

Insulation resistance:

Dielectric strength:

1.2.4 Safety and EMC


Safety regulation:

100 V model:

200 V model:

EMC

100 V model

200 V model

1.2.5 Resistance to Electric Noise


Static electricity:

1.2.6 Environmental Conditions


Temperature:

Operating:

Storage:

Humidity:

Operating:

Storage:

1.2.7 Reliability


Main unit:

Preview:

Scanning:

AP8 Holder:

Scanning:

Door open / close:

Loading:
Rev. A
100 - 120 V AC (100 V model)
220 - 240 V AC (200 V model)
100 - 120 V AC ± 10%
220 - 240 V AC ± 10%
50 - 60 Hz
49.5 - 60.5 Hz
Approx. 10 W (standby)
Max. 50 W
10 M ohms at 500 V DC (between AC line and chassis)
1.5K V AC, 1 min. (200 V model)
1.2K V AC, 1 min. (100 V model)
(between AC Line and chassis)
UL1950 with D3, CSA C22.2 No.950 with D3
EN60950 (TUV)
EN60950 Nordic Deviation
(NEMKO)
FCC Part15 Subpart B Class B :USA
CSA C108.8 Class B
EN55022 Class B
EN61000-3-2
EN61000-3-3
EN 50082-1
IEC 801-2
IEC 801-3
IEC 801-4
Panel - 10K V
Metal - 7K V / 150pF, 150 ohms
5 °C to 35 °C
25 °C to 60 °C
.
10 to 80 %, no condensation
(10 to 65%, when APS option is mounted)
10 to 85 %, no condensation
MCBF 10,000 cycles
MCBF 20,000 cycles
MCBF 10,000 frames
MCBF 1,000 cycles
MCBF 1,000 cycles
GENERAL DESCRIPTION
:Canada
1-
5

Advertisement

Table of Contents
loading