When installing the preview motor, the cable must be twisted four times and is stored inside of the
motor frame., as shown in Figure 3-24.

When mounts the shaft holding plate A, the right side of the plate and the grounding wire for the
optical unit must be fixed by the same screw (Refer to Figure 3-26.).
Rev. A
CN4
Figure 3-25. Micro Switch Board A Removal
ASSEMBLING POINT
Shaft Holding Plate A
Figure 3-26. Grounding Plate A Mounting
DISASSEMBLY AND ASSEMBLY
Hook
CN4
Motor Junction Board
Micro Switch Board A
Grounding
Optical Unit
Screw
Wire From
19