Backplane - Lenovo ThinkSystem SR650 Maintenance Manual

2u rack server
Hide thumbs Also See for ThinkSystem SR650:
Table of Contents

Advertisement

Backplane

Use the section to understand the cable routing for backplanes.
This topic contains the following information:
• "Server models with eight 2.5-inch drives" on page 33
• "Server models with sixteen 2.5-inch drives" on page 38
• "Server models with twenty-four 2.5-inch drives" on page 53
• "Server models with eight 3.5-inch drives" on page 78
• "Server models with twelve 3.5-inch drives" on page 81
Before you route cables for backplanes, observe the adapter priority and the PCIe slot selection priority when
installing the NVMe switch adapter or a RAID adapter.
• Adapter priority: NVMe switch adapter, 24i RAID adapter, 8i RAID adapter, 16i RAID adapter
• PCIe slot selection priority when installing the NVMe switch adapter:
Number of installed processors
One processor
Two processors
• PCIe slot selection priority when installing a 24i RAID adapter:
Number of installed processors
One processor
Two processors
• PCIe slot selection priority when installing a 8i or 16i RAID adapter:
Number of installed processors
One processor
Two processors
Notes:
• The PCIe slot 7 refers to the RAID adapter slot on the system board.
• If the rear hot-swap drive assembly is installed, PCIe slots 1, 2, and 3 will become unavailable because the
space is occupied by the rear hot-swap drive assembly.
32
ThinkSystem SR650 Maintenance Manual
PCIe slot selection priority
1
1, 5, 6
PCIe slot selection priority
1, 2, 3
1, 2, 3, 5, 6
PCIe slot selection priority
7, 4, 2, 3, 1
7, 4, 2, 3, 1, 5, 6