Lenovo ThinkSystem SR650 Maintenance Manual page 49

2u rack server
Hide thumbs Also See for ThinkSystem SR650:
Table of Contents

Advertisement

Server model: sixteen 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, one 24i RAID
adapter
Figure 28. Cable routing for server models with sixteen 2.5-inch SAS/SATA drives, the rear hot-swap drive assembly, and
one 24i RAID adapter
Cable
1
Power cable for front backplane 1
2
SAS signal cable for front
backplane 1
3
SAS signal cable for front
backplane 2
4
Power cable for front backplane 2
5
SAS signal cable for the rear hot-
swap drive assembly
From
Power connector on front backplane
1
SAS 0 and SAS 1 connectors on front
backplane 1
SAS 0 and SAS 1 connectors on front
backplane 2
Power connector on front backplane
2
Signal connector on the rear hot-
swap drive assembly
To
Backplane power connector 1 on the
system board
C0 and C1 connectors on the 24i
RAID adapter installed on PCIe slot 5
C2 and C3 connectors on the 24i
RAID adapter installed on PCIe slot 5
Backplane power connector 2 on the
system board
C4 connector on the 24i RAID
adapter installed on PCIe slot 5
.
Chapter 2
Server components
41