Thermal overload of the external braking resistor must be avoided by
appropriate configuration. If necessary, the converter can be switched
off by a thermoswitch which monitors the temperature of the external
braking resistor (see Fig. 12-1).
SIMOVERT MASTERDRIVES
VC Compact PLUS
-X1
HS1
.21
HS2
Y = Binary input which activates the fault trip of the converter,

Parameterization for the possible binary inputs Y:

Terminal
Binary input
-101.3
1
.4
2
.5
3
.6
4
.7
5
.8
6
-102.19
7
Fig. 12-1
Converter with external braking resistor and fault trip via
thermoswitch
sales@aotewell.com
-X6
G
-X6
H
-X101.1
Y
e.g. -X101.7 (binary input 5)
Parameterization
P586 = 10
P586 = 12
P586 = 14
P586 = 16
P586 = 18
P586 = 20
P586 = 22
Operating Instructions
Industry Automation
05.2003
ext.
braking
resistor
Thermo-
ϑ
switch
6SE7087-6JP60