Edit Mode - Alcatel-Lucent 7950 XRS Series Configuration Manual

Extensible routing system sr os basic system
Table of Contents

Advertisement

Edit Mode

Edit Mode
To enter the mode to edit timing references, you must enter the begin keyword at the
config>system>sync-if-timing# prompt.
Use the following CLI syntax to enter the edit mode:
CLI Syntax: config>system>sync-if-timing
The following error message displays when the you try to modify sync-if-timing parameters
without entering the keyword begin.
A:ALA-12>config>system>sync-if-timing>ref1# source-port 2/1/1
MINOR: CLI The sync-if-timing must be in edit mode by calling begin before any changes can
be made.
MINOR: CLI Unable to set source port for ref1 to 2/1/1
A:ALA-12>config>system>sync-if-timing>ref1#
Page 308
begin
7950 SR OS Basic System Configuration Guide