Replacing Thermistors - Daikin 2MXM50M Service Manual

Ra r32 split & multi split m-series. ftxj-m series;ftxm-m series;ftxp-kv series;fdxm-f series;rxj-m series; rxm-m series;mxm-m series;mxm-n series
Table of Contents

Advertisement

ESIE16-02B
|
Part 3. Repair

3.3.2.11. Replacing thermistors

PRELIMINARY ACTIONS
1.
Switch off the Daikin unit via the user interface.
2.
Switch off the Daikin unit with the field supplied circuit breaker.
3.
Remove plate work when required, see
PROCEDURE
Removal
1.
Locate thermistor that needs to be replaced, see
2.
Cut the tie wraps (1) that fix the insulation (3) and the thermistor wire (2).
3.
Cut the insulation (3) and remove it.
4.
Pull the clip (5) that fixes the thermistor (6).
5.
Remove the thermistor (6) from the thermistor holder (4).
1
2
1
1. Tie wrap
2. Thermistor wire
3. Insulation
Installation
1.
Proceed in reverse order.
4/04/17
|
Version 1.1
RA R32 Split & multi split M-Series
"Basic removal" on page
68.
"Component checklist" on page
Figure 3-17: Replacing a thermistor
3
3.3. Unit specific repair procedures
121.
4
5
4. Thermistor holder
5. Clip
6. Thermistor
6
Page 87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents