ESIE16-02B
|
Part 3. Repair
3.3.2. Outdoor unit
3.3.2.1. Basic removal
3.3.2.1.1 Single fan outdoor unit
3.3.2.1.2 Removing refrigerant connection cover
PRELIMINARY ACTIONS
1.
Switch off the Daikin unit via the user interface.
2.
Switch off the Daikin unit with the field supplied circuit breaker.
PROCEDURE
Removal
1.
Loosen and remove 1 screw (1) that fix the refrigerant connection cover.
1. Screw
3.3.2.1.3 Removing the top plate
PRELIMINARY ACTIONS
1.
Switch off the Daikin unit via the user interface.
2.
Switch off the Daikin unit with the field supplied circuit breaker.
PROCEDURE
Removal
1.
Loosen and remove the 2 screws (1) that fix the top plate.
Page 68
RA R32 Split & multi split M-Series
Figure 3-3: Removing refrigerant connection cover
3.3. Unit specific repair procedures
1
4/04/17
|
Version 1.1