Figure 3-10: Removing The Compressor - Daikin 2MXM50M Service Manual

Ra r32 split & multi split m-series. ftxj-m series;ftxm-m series;ftxp-kv series;fdxm-f series;rxj-m series; rxm-m series;mxm-m series;mxm-n series
Table of Contents

Advertisement

ESIE16-02B
|
Part 3. Repair
1
2
1
1. Screw
2. Partition plate assembly
3. Terminal cover
4. Compressor wiring
5. Compressor pipe
4/04/17
|
Version 1.1
RA R32 Split & multi split M-Series

Figure 3-10: Removing the compressor

8
3 3
8
9
3.3. Unit specific repair procedures
9
6. Nut
7. Compressor
8. Putty
9. Dampers
10. Bushing
3
4
5
8
7
5
Page 77