Piping Diagram; Indoor Unit; Outdoor Unit; 2Mxm40M - Daikin 2MXM50M Service Manual

Ra r32 split & multi split m-series. ftxj-m series;ftxm-m series;ftxp-kv series;fdxm-f series;rxj-m series; rxm-m series;mxm-m series;mxm-n series
Table of Contents

Advertisement

ESIE16-02B
|
Part 5. Appendix

5.4. Piping diagram

5.4.1. Indoor unit

Not applicable.

5.4.2. Outdoor unit

5.4.2.1. 2MXM40M

Branch pipe
7.0CuT
7.0CuT
Heat exchanger thermistor
9.5CuT
9.5CuT
4-way valve
ON: heating
Muffler
Discharge pipe thermistor
Compressor
Page 104
RA R32 Split & multi split M-Series
Figure 5-17: Piping diagram - outdoor unit 2MXM40M
Outdoor air temperature thermistor
Heat exchanger
Branch pipe
6.4CuT
Twin-branched muffler
4.8CuT
4.8CuT
Fan motor
Propeller fan
Muffler
9.5CuT
Muffler
9.5CuT
9.5CuT
Branch pipe
Muffler
Accumulator
Motor-operated valve
EV
Muffler with filter
A
6.4CuT
Filter
Muffler
6.4CuT
Motor-operated valve
EV
Muffler with filter
B
Muffler
Filter
Thermistor (gas)
9.5CuT
9.5CuT
Gas stop valve
Thermistor (gas)
9.5CuT
Gas stop valve
5.4. Piping diagram
Thermistor (liquid)
Room A
(6.4CuT)
6.4CuT
6.4CuT
Liquid stop valve
Field piping
Liquid
Thermistor (liquid)
Room B
(6.4CuT)
6.4CuT
Liquid stop valve
Room A
(9.5CuT)
Field piping
Gas
Room B
(9.5CuT)
Refrigerant flow
Cooling
Heating
4/04/17
|
Version 1.1