Sun Crypto Accelerator 6000; Hardware Documentation Updates - Fujitsu SPARC Enterprise M3000 Product Notes

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

Disable the Volume Management Daemon (vold) before unconfiguring a DVD drive
with the cfgadm(1M) command. To disable vold, stop the daemon by issuing the
command /etc/init.d/volmgt stop. After the device has been removed or
inserted, restart the daemon by issuing the command /etc/init.d/volmgt
start.

Sun Crypto Accelerator 6000

If you are not using the correct version of the Sun Crypto Accelerator (SCA) 6000
driver, hot-plug operations on SCA 6000 can cause the M8000/M9000 servers to
panic or hang. Version 1.1 of the SCA6000 driver and firmware supports hot-plug
operations after the required bootstrap firmware upgrade has been performed.
Version 1.0 of the SCA6000 driver does not support hot-plug and should not be used.

Hardware Documentation Updates

This section contains late-breaking hardware information that became known after
the documentation set was published and corrections in the M8000/M9000 servers
hardware documentation.
TABLE 6-2
Hardware Documentation Updates
TABLE 6-2
Title
SPARC Enterprise
M8000/M9000 Servers
Site Planning Guide
90
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012
lists known documentation updates.
Page Number
Update
1-35
For the order number of Vibration-proof bracket and Vibration-
proof feet, see
"Cabinet Stabilization Measures" on page
91.

Advertisement

Table of Contents
loading

Table of Contents