XCP Issues Fixed in Releases Earlier Than XCP 1112 (Continued)
TABLE 3-3
M4000
ID
M3000
M5000
RTIF1-
O
080325-001
RTIF1-
O
080404-001
32
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012
M8000
M9000 Description
O
M4000/M5000 servers:
When you turn on AC power, or when
you execute the rebootxscf(8)
command, you may become unable to
log in to XSCF and your press on the
POWER switch on the operator panel
may fail to turn on the power.
M8000/M9000 servers:
When you turn on AC power, or when
you execute the rebootxscf(8) or
switchscf(8) command, either of the
following situations may occur.
• Following error message gets
registered in the error log, the status
becomes Faulted, and the standby
XSCF becomes unable to start.
Device error on serial
interconnection between
XSCFUs
• You become unable to log in to XSCF
and your press on the POWER switch
on the operator panel can't turn on
the power.
O
Following a dynamic reconfiguration
operation using the XSCF commands
deleteboard(8) and addboard(8),
you might see I/O channel degradation,
resulting in error messages and entries
in the corresponding ereport.
If you run into this problem, the
fmdump(8) command will report the
following error by mistake:
ereport.chassis.SPARCEnterpris
e. asic.ioc.ch.leaf.fe
Workaround
M4000/M5000 servers:
Before turning on AC power, or
executing the rebootxscf(8)
command, please confirm that XSCF
LAN has been correctly connected and
linked up.
In case the situation in question
occurred, please turn off the power of
all domains and then execute the
system power off/on. To turn on the
power that you turned off, wait at least
30 seconds before power-on.
M8000/M9000 servers:
Before turning on AC power, or
executing the rebootxscf(8) or
switchscf(8) command, please
confirm that XSCF LAN has been
correctly connected and linked up.
In case the situation in question
occurred, please take either of the
following actions.
• Use the replacefru(8) command to
reattach the standby XSCF unit.
• Turn off the power of all domains
and then execute the system power
off/on. To turn on the power that you
turned off, wait at least 30 seconds
before power-on.
The MSG-ID assigned to the error
displayed and the actual behavior may
not be consistent, and reset or
degradation may not occur. Contact a
qualified service engineer and give the
error code that displayed by using the
showlogs error command.

Advertisement