XCP Issues Fixed in Releases Earlier Than XCP 1112 (Continued)
TABLE 3-3
M4000
ID
M3000
M5000
RTIF1-
O
080725-003
RTIF1-
O
O
080725-004
RTIF1-
O
080808-001
RTIF1-
O
O
081006-001
RTIF1-
O
O
081006-002
RTIF1-
O
081006-003
RTIF1-
O
O
081006-004
34
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012
M8000
M9000 Description
O
The initial value that set with the
setdomparam set-defaults option
differs from the initial value of
OpenBoot PROM.
parameters
current value expected
value
diag-level none(0x00)
min(0x20)
auto-boot? false(0x00)
true(0xff)
O
After set the Daylight Saving Time by
using the XSCF shell, XSCF Web does
not show the correct time in the Logs
menu.
O
On the cluster system using the
PRIMECLUSTER software, when there
are 10 or more RCI units, the RCI busy
status may be temporarily unreleased
and output the following syslog
message:
SA_pprcir.so to test host
host_name failed
O
The error log "XSCF FMEM write
error" recorded and the firmware
update might fail.
O
In the setemailreport(8) command,
when you specified over 255 characters
in the SMTP address, an error results.
During the domain operation, after the
XSCF reset due to the XSCF unit failure,
the hardware status shows
Deconfigure in the status of CPU and
memory.
O
During the firmware update, there
might be the following output message
and a XSCF panic might occur.
kernel BUG in
jffs2_do_read_inode at
fs/jffs2/readinode.c:XXX!
Workaround
In the OpenBoot PROM prompt (ok),
execute the set-defaults command
to restore the OpenBoot PROM
environmental variables to the initial
value.
No workaround is available.
Use the showlogs(8) command of the
XSCF shell.
Refer to the manual of the
PRIMECLUSTER software to check the
cluster status. If no problem found on
the status, this message can be safely
ignored. If any problem, follow the
instructions on the manual to solve the
problem.
Power off (AC OFF) the system, and
power on (AC ON) again. Then, re-
execute the firmware update.
Do not specify over 255 characters in
the SMTP address.
Replace the motherboard unit only.
When no failure found on the memory,
you do not need to replace the memory.
Reset XSCF and use the
flashupdate(8) command to retry the
firmware update.

Advertisement