Notes on the Use of USB Memory

To execute the dumpconfig(8), restoreconfig(8) or snapshot(8) command, if
you specify USB memory as the destination to store data, prepare the USB memory
as a medium in advance.
The data stored will include the information about the system. To use USB memory,
you need to pay attention to the management of the USB memory in which the data
stored, from the data security viewpoint.
We do not provide guarantees to every USB memory from any manufacturers that
currently on the market against its connectivity to XSCF and proper operation.
Depending on the USB memory in use, defects such as the XSCF firmware error or
reset may occur. In case such defects occurred, stop the use of USB memory
immediately.
To connect the USB memory to the USB port for XSCF, connect the USB memory
directly to the USB port. If connected via USB hub or USB extension cables, it may
cause errors.

Power Control and Operator Panel Mode Switch

Note – Before using the RCI function, see
"Notes on RCI Function" on page
13.
When you use the remote power control utilizing the RCI function or the automatic
power control system (APCS), you can disable this remote power control or the
APCS by setting the mode switch to Service mode on the operator panel.
Disabling these features ensures that you do not unintentionally switch the system
power on or off during maintenance. Note that system power off with the APCS
cannot be disabled with the mode switch. Therefore, be sure to turn off automatic
power control via APCS before starting maintenance.
82
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012