Fujitsu SPARC Enterprise M3000 Product Notes page 34

Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

XCP Issues Fixed in Releases Earlier Than XCP 1112 (Continued)
TABLE 3-3
M4000
ID
M3000
M5000
RTIF1-
O
070418-020
RTIF1-
O
070418-021
RTIF1-
O
070418-022
RTIF1-
O
070418-023
RTIF1-
O
070418-025
RTIF1-
O
070528-001
RTIF1-
O
O
070528-002
RTIF1-
O
070802-001
20
SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1112 • May 2012
M8000
M9000 Description
O
When using the XSCF Web to import a
firmware image, if the image is
corrupted (for example, if the browser
window is closed during import), the
flashupdate command might later
report an internal error.
CR ID 6537996 is similar.
O
Attempting to move a COD board using
the moveboard(8) command might fail.
O
The XSCF firmware monitors itself and
if it detects any abnormalities, it will
force a reset.
O
Using the rebootxscf(8) command
may result in a process down error, and
possibly an FMA event with MSG ID
SCF-8005-NE.
O
showaudit all shows a long list of
defaults in the policy section after the
database is cleared.
O
When you have updated the
/etc/ttydefs file of Oracle Solaris OS
to disable the console flow control, you
cannot disable the console flow control
on the telnet via a server.
O
While XSCF is running, watchdog
timeout may occur and XSCF may
reboot.
O
When connected to telnet, the login or
the password prompt doesn't appear.
Workaround
Use the command getflashimage -d
to delete the corrupted image. If
necessary, reboot the XSCF Unit, then
use the flashupdate command again
to clear the internal error.
Use the deleteboard(8) and
addboard(8) commands instead of the
moveboard(8) command.
Allow the XSCF Unit to finish resetting.
It will return to normal operation
within approximately 5 minutes.
Ignore this event.
Update the database with the following:
setaudit -a opl=enable
setaudit -a opl=default
No workaround is available.
M4000/M5000/M8000/M9000 servers:
Check that XSCF is started. If not
started, stop all the domains and then
execute the system power off/on (AC
OFF/ON). To turn on the system power
that you turned off, wait at least 30
seconds before power-on.
M3000 server:
Check that XSCF is started. If not
started, stop the domain and then
execute the system power off/on (AC
OFF/ON). To turn on the system power
that you turned off, wait at least 30
seconds before power-on.
Disconnect the telnet session and try
again.

Advertisement