Adjustment
13
Looper motion
.05.22
● Insert a new needle.
● Turn the handwheel until the point of the looper, coming from the right hand side, is on the
● In this position, fasten the screw clamp (Part No. 08-880 137-00) onto the needle bar so
● Turn the needle bar back until the screw clamp is once again touching it.
● Check requirement.
● If necessary, remove the screw clamp and turn the cog 1 (screws 2) according to the
13 - 25
Requirement
The needle bar position must be the same:
a) when the point of the looper, coming from the right hand side, is positioned to the left
hand side of the needle and,
b) when, after the handwheel has been turned back, the looper point is positioned a) to the
right hand side of the needle.
2
Fig. 13 - 22
left hand side of the needle.
that the upwards movement of the needle bar is blocked.
requirement.
1