Adjustment
13
Adjusting the basic machine
.05
13
Basic position of the machine
.05.01
● Switch on the machine.
● Call up the input mode.
● Call up parameter "301".
● By turning the balance wheel, position the needle point flush to the top edge of the needle
● Conclude the input.
● Switch off the machine.
13 - 3
plate.