IBM DS8000 User Manual page 190

Hide thumbs Also See for DS8000:
Table of Contents

Advertisement

SEC: xxx tttt-ooo pp-zzzzz ll
Path: Type PP PLink SP SLink RC
1: aaaaa bbbb cccccc dddd eeeeee gg
.
.
.
w: aaaaa bbbb cccccc dddd eeeeee gg
where yyyy/MM/dd hh:mm:ss tzn is the time that the alert was sent
(year, month, day, hour, minute, second, and time zone);
-error_description- is the event description; xxx is the manufacturer;
tttt-ooo is the machine type and model number; pp-zzzzz is the
serial number (a combination of the plant of manufacture and the
sequence number); ll is the LSS number in hexadecimal format;
aaaaa is "ESCON" or "FIBRE"; bbbb is the primary I/O port number;
cccccc is the primary link address in hexadecimal format; dddd is
the secondary port number for ESCON direct connection or FIBRE
(this value is XXXX if you are connected through an ESCON
switch); eeeeee is the secondary link address in hexadecimal format;
gg is the reason code in hexadecimal format (see Table 5 on page
160) if there is a problem (otherwise, gg is "OK" if there is no
problem); and w represents the last of up to 8 path descriptions.
Only established paths are listed.
Specific trap 102 - Remote mirror and copy links are operational
This trap displays when an established remote mirror and copy
path between a primary and secondary logical subsystem pair
becomes operational after previously being inoperable. All other
established paths between the two logical subsystems are
operational. The following information is shown for specific trap
102:
ssEventDescr=yyyy/MM/dd hh:mm:ss tzn
-error_description-
UNIT: Mnf Type-Mod SerialNm LS
PRI: xxx tttt-ooo pp-zzzzz ll
SEC: xxx tttt-ooo pp-zzzzz ll
Path: Type PP PLink SP SLink RC
1: aaaaa bbbb cccccc dddd eeeeee gg
.
.
.
w: aaaaa bbbb cccccc dddd eeeeee gg
where yyyy/MM/dd hh:mm:ss tzn is the time that the alert was sent
(year, month, day, hour, minute, second, and time zone);
-error_description- is the event description; xxx is the manufacturer;
tttt-ooo is the machine type and model number; pp-zzzzz is the
serial number (a combination of the plant of manufacture and the
sequence number); ll is the LSS number in hexadecimal format;
aaaaa is "ESCON" or "FIBRE"; bbbb is the primary I/O port number;
cccccc is the primary link address in hexadecimal format; dddd is
the secondary port number for ESCON direct connection or FIBRE
(this value is XXXX if you are connected through an ESCON
switch); eeeeee is the secondary link address in hexadecimal format;
gg is the reason code in hexadecimal format (see Table 5 on page
160) if there is a problem (otherwise, gg is "OK" if there is no
problem); and w represents the last of up to 8 path descriptions.
Only established paths are listed.
162
DS8000 User's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents