Power Meter Results

A
The current power meter reading and the
minimum and maximum readings since the test
began. The reading shows Too Low if the
power is below or above the tester's
measurement range.
W
Caution
If the power reading is above the tester's
range, immediately disconnect the source
from the tester. The tester is not designed
for measuring higher power levels, such as
produced by CATV, optical amplifiers, and
cellular systems.
To toggle between dBm (decibels relative to
1 mW) and µW (microwatts), press
To restart the recording of minimum and
maximum values, press
B
The wavelength being measured. To change
the wavelength, press
A
.
C
Reset Min Max.
B
Change Wavelength.
Figure 8-3. The Power Meter Screen
2
1
C
The current End setting on the Job tab in SETUP.
D
To add comment to be saved with the power meter results,
D
press
Edit Comment.
Using the Power Meter Option