YASKAWA CIMR-F7A Instruction Manual page 334

Varispeed f7 general purpose inverter
Hide thumbs Also See for CIMR-F7A:
Table of Contents

Advertisement

Con-
stant
Name
Num-
ber
ASR pro-
Usually setting is not necessary.
C5-03
portional
Set to change the rotational speed gain.
(P) gain 2
P I
ASR inte-
C5-04
gral (I) time
0
2
Sets the upper limit for the compensa-
tion frequency for the speed control
C5-05 ASR limit
loop (ASR) to a percentage of the max-
imum output frequency.
Sets the filter time constant for output-
ASR pri-
ting torque references from the speed
C5-06
mary delay
control loop (ASR). It is set in 1-second
time
units.
Usually setting is not necessary.
Sets the frequency for switching
ASR
between Proportion Gain 1, 2 and Inte-
C5-07
switching
gral Time 1, 2 in Hz units.
frequency
The multi-function input "ASR switch-
ing proportional gain" has the priority.
Sets the upper limit for the integral (I)
ASR inte-
C5-08
amount for the speed control loop
gral (I) limit
(ASR) to a percentage of the rated load.
* 1. When using V/f with PG control, 0.00 to 300.00. The flux vector setting ranges are given.
* 2. When the control method changes, the factory setting is changed. The flux vector control factory settings are given. Refer to
Factory Settings that Change with the Control Method (A1-02).
* 3. When C6-01=1, the upper limit is 400.0.
Multi-function Contact Input Functions (H1-01 to H1-06)
Set-
ting
Value
Speed control disable setting for V/f control with PG
D
OFF: Use speed control V/f control with PG
ON: Do not use speed control for V/f control with PG
Speed control integral reset
E
Enables switching between PI and P control for the speed control loop.
Speed control (ASR) proportional gain switch (switching between C5-01 and C5-03)
77
OFF: Use proportional gain in C5-01
ON: Use proportional gain in C5-03
Setting
Description
Range
1.00 to
300.00
*1
P=C5-01
I=C5-02
P=C5-03
I=C5-04
0.000
to
E1-04
Motor speed (Hz)
10.000
0.0 to
20.0
0.000
to
0.500
0.0 to
300.0
*3
0 to
400
Function
Control Methods
Change
Open
Factory
during
V/f
Loop
Setting
Opera-
V/f
with
Vec-
tion
PG
tor
20.00
Yes
No
A
No
*2
0.500 s
Yes
No
A
No
*2
5.0%
No
No
A
No
0.004 s
No
No
No
No
0.0 Hz
No
No
No
No
400%
No
No
No
No
Control Methods
V/f
V/f
with
PG
No
Yes
No
No
No
No
Individual Functions
MEMO
BUS
Flux
Regis-
Vec-
ter
tor
A
21DH
A
21EH
No
21FH
A
220H
A
221H
A
222H
Open
Flux
Loop
Vec-
Vec-
tor
tor
No
No
No
Yes
No
Yes
137
6-