DC Injection Braking: b2
User constants for injection braking are shown in the following table.
Con-
stant
Number
Zero-speed
level (DC
injection
b2-01
braking
starting fre-
quency)
DC injec-
b2-02
tion brak-
ing current
DC injec-
tion brak-
b2-03
ing time at
start
DC injec-
tion brak-
b2-04
ing time at
stop
Magnetic
flux com-
b2-08
pensation
volume
-12
5
Name
Description
Used to set the frequency
which starts DC injection
braking in units of Hz when
deceleration to stop is
selected.
When b2-01 is less than E1-
09, E1-09 is used to set the
starting frequency for the
DC injection braking.
In flux vector control, b2-01
is used to set the starting fre-
quency for the zero-speed
control.
Sets the DC injection brak-
ing current as a percentage
of the Inverter rated current.
The DC injection braking
current in flux control is
affected by any change to the
setting of E2-03.
Used to set the time to per-
form DC injection braking at
start in units of 1 second.
Used to stop coasting motor
and restart it. When the set
value is 0, DC injection
braking at start is not per-
formed.
Used to set the time to per-
form DC injection braking at
stop (zero-speed control in
flux vector control) in units
of 1 second.
Used to prevent coasting
after the Stop Command is
input. When the set value is
0.00, DC injection braking at
stop is not performed.
Sets the magnetic flux com-
pensation as a percentage of
the no-load current.
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0.0 to
0.5 Hz
No
A
10.0
0 to
50%
No
A
100
0.00
to
0.00 s
No
A
10.00
0.00
to
0.50 s
No
A
10.00
0 to
0%
No
No
1000
MEMO
Open
BUS
V/f
Flux
Page
Loop
Regis-
with
Vec-
Vec-
ter
PG
tor
tor
6-17
A
A
A
189H
6-145
6-18
A
A
No
18AH
6-22
6-18
A
A
A
18BH
6-22
A
A
A
18CH 6-18
No
A
A
190H
-