Watch Window Errors; Debug Errors; Timing Chart Errors - Omron WS02-CFSC1-E Operation Manual

Table of Contents

Advertisement

Operating Errors and Countermeasures
5-1-3

Watch Window Errors

5-1-4

Debug Errors

5-1-5

Timing Chart Errors

Error message
Tags were regis-
You tried to add more than the limit of 100 tags in total on the
tered up to the limit
Watch Window. Up to 100 tags will be registered but the
of 100 tags. Tags
remaining tags will not be registered. Add them to a different
exceeding this limit
tab or delete unwanted tags before trying to add more.
were not registered.
The limit of 100 tags
You tried to add more tags when the limit of 100 tags has
has already been
already been registered. Add them to a different tab page or
registered.
delete unwanted tags before trying to add more.
Error message
Specify the delay in
The delay value of the feedback setting has not been specified
increments of 10 ms.
in increments of 10 ms. It must be entered in increments of
10 ms.
Specify the time in
The pulse input ON time or OFF time has not been specified
increments of 10 ms.
in increments of 10 ms. It must be entered in increments of 10
ms.
The feedback set-
The input tag that you tried to use for feedback setting already
ting has already
has feedback setting. To overwrite the setting, click the Yes
been made for this
Button, otherwise click the No Button.
input tag. Overwrite
it?
The limit of 200 con-
You tried to add more than the limit of 200 conditional expres-
ditional expressions
sions for the feedback setting You cannot register more than
has already been
200 conditions. Delete conditions that are no longer required
registered.
before adding new ones.
The pulse input
You tried to use the input pulse operation while it is already
operation is already
being executed. To stop the pulse input operation and apply a
being executed. OK
new pulse input, click the Yes Button. To continue the previous
to stop the opera-
pulse input, click the No Button.
tion?
Error message
Tags were regis-
You tried to add more than the limit of 1,000 tags in total on
tered up to the limit
the Timing Chart Window. Delete tags that are no longer
of 1,000 tags. Tags
required before trying to add more.
exceeding this limit
You can also use the timing chart import/export function to
were not registered.
switch between multiple timing chart files for debugging
The I/O break condi-
A tag that was registered as an I/O break condition has been
tion registered for the
deleted from the timing chart. It will be deleted from the I/O
tag that was deleted
break condition.
was removed from
the timing chart.
The I/O breakpoint is
An I/O breakpoint is set but is not enabled. To enable the I/O
disabled. Do you
breakpoint click the Yes Button, to leave it disabled click the
want to enable it?
No Button.
The limit of 10 condi-
You tried to add a new condition when the number of condi-
tional expressions
tions registered with the I/O breakpoint has already reached
has already been
its limit of 10. Only up to 10 conditions can be added. Delete
registered.
conditions that are no longer required before trying to add
more.
Section 5-1
Countermeasure
Countermeasure
Countermeasure
61