I/O Breakpoint

4-10 I/O Breakpoint

4-10-1 I/O Breakpoint Settings

1,2,3...
56
An I/O breakpoint can be used to pause the timing chart depending on I/O
status (ON or OFF).
1. Select Breakpoints - I/O Breakpoint - Setting.
The setting screen consists of the following parameters.
Parameter
Register Break Con-
Select the tags that are used as conditions for the I/O break-
ditions
point. Set the Condition Option to ON or OFF, and then click
the Add Button.The tag will be added to the Applied Condi-
tions List. Up to ten tags can be assigned to one I/O break-
point as conditions.
Applied Conditions
Displays a list of conditions for the I/O breakpoint.Select a
List
condition from the list and click the Delete Button to delete the
selected condition.
Logic between Con-
If AND is selected, the timing chart will stop when all the
ditions
applied conditions are met. If OR is selected, the timing chart
will stop when at least one of the applied conditions is met.
2. Make the settings as required and click the OK Button.