7.6.4 Connecting the SMA Power Injector with Bluetooth to the
power supply
Requirements
• The NetID of your PV system is set on the SMA Power Injector with Bluetooth (see section
6.4.3 "Determining the mounting/installation location" (page 36)).
• "MODE 0" is set on the SMA Power Injector with Bluetooth (see section 6.4.3 "Determining the
mounting/installation location" (page 36)).
• All devices are connected.
• The inverter and the communication devices have all been switched on.
Procedure
Power can be supplied in three different ways:
• The plug-in power supply unit included in the delivery.
• Alternate power sources (AC or DC).
Power from the Plug-in power supply unit
1. Connect the DC plug of the plug-in power supply unit to the DC terminal of the SMA Power
Injector with Bluetooth.
2. Attach the relevant country adapter to the plug-in power supply unit.
3. Insert the plug-in power supply unit into a power outlet.
☑ The SMA Power Injector with Bluetooth is connected to the power supply. The "RDY" LED glows
green continuously. It takes about one to two minutes for the Sunny SensorBox to start up once
it is connected to the power supply. The blue Bluetooth LED on the SMA Power Injector with
Bluetooth glows continuously. Following initial startup, it can take three to four minutes before
the Sunny SensorBox is ready for use.
– If the "RDY" LED on the SMA Power Injector with Bluetooth does not light up, refer to section
11 "Troubleshooting" (page 74).
– If the blue Bluetooth LED on the SMA Power Injector with Bluetooth does not glow
continuously, refer to section 11 "Troubleshooting" (page 74).
The startup procedure of the Sunny SensorBox is complete. You can now detect the Sunny SensorBox
with a communication product (e.g., the Sunny WebBox with Bluetooth or Sunny Explorer) and view
the data collected by the sensors.