SonicWALL SMA 200 Getting Started Manual page 41

Hide thumbs Also See for SMA 200:
Table of Contents

Advertisement

Scenario A: Connecting the SMA 
on a New DMZ
The following procedures explain how to configure your 
gateway appliance based on Scenario A:
Connecting the SMA to the Gateway on page 40
Allowing a WAN to SMA Connection on page 40
Allowing an SMA to LAN Connection on page 42
Connecting the SMA to the Gateway 
To connect the SMA 200/400 using Scenario A:
1 Connect one end of an Ethernet cable to an unused 
port on your SonicWall gateway appliance.
2 Connect the other end of the Ethernet cable to the X0 
port on the front of your SonicWall Secure Mobile 
Access 200/400. The X0 Port LED lights up indicating an 
active connection.
3
Configure the SMA X0 IP address. Refer to Configuring 
the X0 IP Address on page 34.
40
SonicWall Secure Mobile Access 200/400 Getting Started Guide
Allowing a WAN to SMA Connection
NOTE: Before continuing, you must add a new SMA 
custom zone. Refer to Adding a New SMA Custom Zone 
on page 38 for more information. 
To allow a WAN to SMA connection:
1 Click the Wizards icon in the top right corner of the 
gateway appliance management interface.
2 On the Welcome page, select the Public Server Guide, 
and then click Next.