HP A6600 Configuration Manual page 294

Ip multicast
Hide thumbs Also See for A6600:
Table of Contents

Advertisement

To do...
2.
Enter MLD view.
3.
Configure the MLD querier's
robustness variable.
4.
Configure the startup query
interval.
5.
Configure the startup query
count.
6.
Configure the MLD query
interval.
7.
Configure the maximum
response delay for MLD
general query messages.
8.
Configure the MLD last listener
query interval.
9.
Configure the MLD other
querier present interval.
Configuring MLD query and response parameters on an interface
To do...
1.
Enter system view.
Enter interface view.
2.
3.
Configure the MLD querier's
robustness variable.
4.
Configure the startup query
interval.
5.
Configure the startup query
count.
Use the command...
mld
robust-count robust-value
startup-query-interval interval
startup-query-count value
timer query interval
max-response-time interval
last-listener-query-interval interval
timer other-querier-present
interval
Use the command...
system-view
interface interface-type
interface-number
mld robust-count robust-value
mld startup-query-interval interval
mld startup-query-count value
283
Remarks
Optional.
2 times by default.
Optional.
By default, the startup query
interval is 1/4 of the "MLD query
interval".
Optional.
By default, the startup query count
is set to the MLD querier's
robustness variable.
Optional.
125 seconds by default.
Optional.
10 seconds by default.
Optional.
1 second by default.
Optional.
By default, the other querier
present interval is determined by
the formula "Other querier present
interval (in seconds) = [ MLD
query interval ] × [ MLD querier's
robustness variable ] + [ maximum
response delay for MLD general
query ] /2".
Remarks
Optional.
2 times by default.
Optional.
By default, the startup query
interval is 1/4 of the "MLD query
interval".
Optional.
By default, the startup query count
is set to the MLD querier's
robustness variable.

Advertisement

Table of Contents
loading

Table of Contents