Diagnostics
Table 11: MAP 600 Event Codes (Continued)
Event
Code
140
142
150
5
Go to the Web browser PC accessing the switch's EWS interface.
Does the EWS interface appear operational?
YES
6
Inspect the Fibre Channel port segmentation reason at the EWS interface.
1. At the View panel, click the Port Properties tab. The View panel opens with
2. Click the port number (0 through 11) of the segmented port.
3. Inspect the Reason field for the selected port.
Is the Reason field blank or does it display an N/A message?
NO
The Reason field displays a segmentation reason message.
reasons and suggested actions to isolate faults.
Table 12: Port Segmentation Reasons and Actions
Incompatible operating parameters.
Duplicate domain ID.
Incompatible zoning configurations.
78
Congestion detected on an ISL.
Low BB_Credit detected on an ISL.
Zone merge failure.
NO
Analysis for an Ethernet link, AC power distribution, or CTP failure
is not described in this MAP. Go to
page 32. If this is the second time at this step, contact the next level of
support. Exit MAP.
the Port Properties page displayed.
YES
The switch ISL appears operational. Exit MAP.
Segmentation Reason
Explanation
Action
Go to
step
21.
Go to
step
22.
Go to
step
23.
"MAP 0000: Start
MAP" on
Table 12
Action
Go to
step
13.
Go to
step
14.
Go to
step
15.