System Events (000 through 199)

Table 18: Event Code 011
Message:
Login Server database invalid.
Severity:
Minor.
Explanation:
Following an initial machine load (IML) or firmware download, the Login Server
database failed its cyclic redundancy check (CRC) validation. All Fabric Services
databases are initialized to an empty state, resulting in an implicit Fabric logout of
all attached devices.
Action:
Perform the procedure described in
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Table 19: Event Code 021
Message:
Name Server database invalid.
Severity:
Minor.
Explanation:
Following an IML or firmware download, the Name Server database failed its CRC
validation. All Fabric Services databases are initialized to an empty state, resulting
in an implicit Fabric logout of all attached devices.
Action:
Perform the procedure described in
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
"Collect Maintenance Data" on page
E-Mail
Call
Home
"Collect Maintenance Data" on page
E-Mail
Call
Home
Event Codes
105.
Host
Sense
Link
Info
Incident
105.
Host
Sense
Link
Info
Incident
135

Advertisement

Table of Contents
loading

Table of Contents