CTP Card Events (400 through 499)

Table 47: Event Code 400
Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field replaceable unit (FRU) as
indicated by the event data.
Action:
If a CTP card failure is indicated, replace the switch. If a fan or power supply failure
is indicated, replace the switch. Perform the procedure described in
Maintenance Data" on page
Event Data:
Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply
assembly.
Byte 1 = FRU slot number.
Distribution:
Switch
EWS
Event
Log
Table 48: Event Code 410
Message:
Switch reset.
Severity:
Informational.
Explanation:
The switch reset due to system power-up, IML, or manual reset. A software reset can
occur automatically after a firmware fault (event code 411), or be user-initiated.
Event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/12 Service Manual
105.
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
"Collect
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
155

Advertisement

Table of Contents
loading

Table of Contents