display oam configuration

oam errored-symbol threshold

Use oam errored-symbol threshold to set the errored symbol event triggering threshold.
Use undo oam errored-symbol threshold to restore the default.
Syntax
oam errored-symbol threshold threshold-value
undo oam errored-symbol threshold
Default
The errored symbol event triggering threshold is 1.
Views
System view
Default command level
2: System level
Parameters
threshold-value: Errored symbol event triggering threshold, ranging from 0 to 4,294,967,295.
Examples
# Set the errored symbol event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-symbol threshold 100
Related commands
oam errored-symbol period
display oam link-event
display oam configuration

oam mode

Use oam mode to set the Ethernet OAM mode for an Ethernet port.
Use undo oam mode to restore the default.
Syntax
oam mode { active | passive }
undo oam mode
Default
An Ethernet OAM-enabled Ethernet port operates in the active Ethernet OAM mode.
Views
Layer 2 Ethernet interface view
Default command level
2: System level