Battery Unit; Description Of Figure - IBM DS4200 Installation, User's, And Maintenance Manual

Express storage subsystem
Hide thumbs Also See for DS4200:
Table of Contents

Advertisement

Figure 5. Battery unit
Table 4. Description of Figure 5
Number
1
2
3
4
The battery unit provides backup power to each controller's cache memory. Each
battery unit contains a sealed, rechargeable lithium ion battery. The battery unit can
maintain data in the cache for three days.
The battery chargers in the power supply and fan units perform a battery test when
the storage subsystem is started and on a regularly scheduled interval thereafter.
Data caching starts after the battery completes its battery tests.
The battery unit is hot-swappable. You can remove the battery unit for servicing and
then reinsert it while the DS4200 Express continues to perform I/O operations.
However, write I/O caching is disabled when the battery is in a failed state or
removed from the DS4200 Express controller battery slot. Replace the failed battery
as soon as possible to minimize the time that the write IO caching is disabled.
Information about the condition of the battery unit is conveyed by indicator LEDs on
the front of battery unit. ("Battery unit LEDs" on page 90 identifies the indicator
LEDs on the battery unit and explains the conditions that each LED indicates.)
12
IBM System Storage DS4200 Express Storage Subsystem: Installation, User's and Maintenance Guide
3
4
1
Description
Controller A cache backup battery unit
Controller B cache backup battery unit
Latch
Pull handle
2

Advertisement

Table of Contents
loading