Go to the Subsystem Management window and select View → Storage Subsystem
Profile. When the Storage Subsystem Profile window opens, select the All tab and
scroll through the Profile For Storage Subsystem list to locate the following
information.
Note: The Profile For Storage Subsystem list contains all the profile information for
the entire subsystem. Therefore, it may be necessary to scroll through a
large amount of information to locate the firmware version numbers.
DS4000 Storage Server
v NVSRAM version
v Appware version
v Bootware version
Drives
v Drive firmware version
v ATA translator card firmware version
Note: The ATA translator card firmware and drive firmware are typically
packaged together as a single drive firmware upgrade file.
ESM
v
ESM card firmware version
Method Two:
Complete the appropriate procedure to obtain the specified firmware version.
To obtain the controller firmware version:
Right-click the Controller icon in the Physical View pane of the Subsystem
Management window and select Properties. The Controller Enclosure
properties window opens and displays the properties for that controller.
You must perform this step for each individual controller.
To obtain the drive firmware version:
Right-click the Drive icon in the Physical View pane of the Subsystem
Management window and select Properties. The Drive Properties window
opens and displays the properties for that drive.
You must perform this step for each individual drive.
To obtain the ESM firmware version:
1. In the Physical View pane of the Subsystem Management window, click
the Drive Enclosure Component icon (which is the icon furthest to the
right.) The Drive Enclosure Component Information window opens.
2. Click the ESM icon in the left pane. The ESM information displays in the
right pane of the Drive Enclosure Component Information window.
3. Locate the firmware version of each ESM in the drive enclosure.
To obtain the drive enclosure component firmware version:
1. Click the Drive Enclosure Component icon (which is the right most icon)
in the Drive Enclosure frame in the Physical View pane of the
Subsystem Management window. The Drive Enclosure Component
Information window opens.
2. Click the ESM icon in the left pane. The ESM information displays in the
right pane of the Drive Enclosure Component Information window.