SERVICE SWITCH

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Remove the service access door from the
metercase.
3. Remove one 5/16" hex head screw to
release the bracket that holds the service
switch.
4. Remove the switch, bracket and wire
harness.
NOTE: It is quite easy to incorrectly install
the Service and Vault Switch wire harness.
Mark the wires for the switch that they go to
prior to disassembly. This will make it much
easier to remember the correct orientation
and avoid a miss-wired issue.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Open the washer top (See page 4-3).
5/16" Hex
Head Screw
4-51

MAIN TOP SUPPORT

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
NOTE: There are two parts that make up
the top support. The angled brace is glued
to the underside of the top. The flat brace
is attached to the side panels with a 1/4"
hex screw at each end and it has 3 foam
pads stuck to it. When the top is closed,
the upper angled brace presses into the
glued on foam pads of the lower brace to
help reduce vibration of the coin vault. The
factory installs the braces on the non-coin
model, but they are not needed and can be
removed or discarded if they come loose.
Angled Brace
Foam Pads
Flat Brace