Water Inlet Valves - Whirlpool CHW9050 Service Manual

Commercial he front loading washers
Hide thumbs Also See for CHW9050:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the washer hoses from the hot and
cold water inlet valves.
4. Open the washer top (See page 4-3).
Water Inlet
Valves
5. Lift The locking tabs and disconnect the
wire connectors to the water inlet valves.
The blue connector is for the hot water
valve number 1, the white connector is for
cold water valve number 3 and the grey
connector is for cold water valve number 2.
6. Loosen the clamp and disconnect the hose
from each water inlet valve.

WATER INLET VALVES

7. Remove the T-20 screw, at the back of the
8. From inside of the washer, twist the valve
9. The screens inside the water inlet valves
4-10
Inlet Hoses
& Clamps
washer, securing each water inlet valve.
body to align the locking tabs with the cut-
outs in the back panel. Pull the valve out of
the hole in the panel.
can be cleaned from the back of the washer,
without removing the water inlet valves.
NOTE: (See page 4-35) for photos and for
how to remove the water inlet valves from
the back.
Locking Tab
Water Inlet
Valve Screws

Hide quick links: