Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Open the washer top (See page 4-3).
4. Remove four T-20 1/4" hex head screws,
two at each end, that secure the control
panel to the washer.
Left end
Four T-20 1/4"
Hex Head Screws

CONTROL PANEL

5. Lift the control panel up to release the 2
6. Rotate the control panel down to access the
7. To disconnect the ground wire, depress the
8. To disconnect the wire harness from the
Right end
9. Each Rast connector has keyed tabs
10. The control panel has brass inserts
4-4
tabs from the top edge of the washer.
2 Tabs
components located behind it.
locking tab and pull connector off the spade
which is secured to the control panel with a
screw.
CCU to the UIC depress the locking tab
with a flat blade screwdriver. Pull the Rast
connector off the edge board connector.
at the top which are located in different
places on each connector to assist in
proper placement of the connector during
reassembly.
Rast
Connectors
Keypad Ribbon
that can be removed and changed if they
become stripped. The brass inserts are
threaded on the outside and on the inside.
Use a pair of pliers to unscrew the insert
from the control panel.
Ground Wire
Connection
Connector