CHEMICAL DISPENSER ASSEMBLY
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the control panel bracket
(See page 4-7).
4. Remove two 1/4" hex screws to remove the
cross brace below the top (See page 4-51).
5. Remove the hoses to the water inlet valves
from the back of the chemical dispenser.
Make note which hose is connected to
which inlet.
6. There is a water metering insert in the end
of this hose. Remove it, if necessary, by
pulling it out of the end of the hose.
Water Inlet
Valve Hoses
Chemical
Dispenser
7. Slide the chemical dispenser toward the
back of the washer to release the tab
securing it to the left side panel.
8. Remove the clamp securing the dispenser
outlet hose to the bottom left front corner of
the chemical dispenser and remove hose.
Keyhole
Slot
Outlet Hose
REASSEMBLY NOTE: When reconnecting
the dispenser outlet hose, align the arrow
on the tube with the line on the chemical
dispenser. Align the arrow on the flanged
end of the tube with the arrow on the outer
tub at approximately the 1:00 position.
Arrow On
Tube
Cross
Brace
4-14
Dispenser
Tab
Line On
Chemical
Dispenser
Arrow On
Flanged End