Tub-To-Pump Hose - Whirlpool CHW9050 Service Manual

Commercial he front loading washers
Hide thumbs Also See for CHW9050:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Remove the lower service panel
(See page 4-21).
4. Place a towel or shallow pan below the
pump to catch any water that may be left in
the system.
5. Unscrew the pump filter and pull it out of the
pump. If necessary, use a pair of pliers to
loosen it.

TUB-TO-PUMP HOSE

Drain Pump Filter
4-25
6. Remove the hose clamp from the pump and
remove the hose.
7. Remove the pressure switch hose from the
air trap which is connected to the tub-to-
pump hose with a wire tie.
NOTE: When removing only the air hose
from the tub-to-pump hose, avoid breaking
the nipple of the fitting since it is a tight fit.
Instead, cut off the wire tie securing the
fitting to the tub-to-pump hose, and remove
the fitting with the air hose. The wire tie will
need to be replaced if this is the procedure
used.
8. Remove the hose clamp from the outer tub
and remove the tub-to-pump hose.
Tub Hose
Clamp
Tub-To-Pump Hose
Pressure Switch Hose
Air Trap
Wire Tie
Pump Clamp