Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Disconnect Power to the washer.
2. Open and remove the service access door
on top of the metercase.
3. Disconnect the coin slide wire harness
from either the coin slide switch or the 4 pin
connector in the metercase.
4. Remove the 5/16" hex coin slide retaining
bolt from inside the service opening at the
top of the metercase.
5/16" Hex

COIN SLIDE MECHANISM

Bolt
5. Lift the coin slide up to release it from the
coin slide adapter plate and remove it from
the front of the metercase.
NOTE: Coin slide mechanism may be
installed very tight and need a little coaxing
to remove. Adjustment screws to loosen
this fit can be accessed from behind the
coin slide face plate once the coin slide is
removed.
6. Coin slide shown below with coin slide
extension and switch with wire harness
attached.
4-45
Coin Slide
Adapter Plate
4 Adjustment
Screws