Mitsubishi Electric MR-J4 Instruction Manual page 529

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

17. APPLICATION OF FUNCTIONS
2) One-touch tuning execution
After the response mode is selected in 1), pushing the start button during servo motor driving will
start one-touch tuning. If the start button is pushed while the servo motor stops, "C 0 0 2" or "C 0
0 4" will be displayed at status in error code. (Refer to 4) in this section for error codes.)
During processing of one-touch tuning, the status will be displayed in the progress window as
follows. One-touch tuning will be finished at 100%.
Completing the one-touch tuning starts writing tuning parameters to the servo amplifier. "0 0 0 0"
is displayed at status in error code. In addition, settling time and overshoot amount will be
displayed in "Adjustment result" after adjustment.
POINT
For equipment in which overshoot during one-touch tuning is in the permissible
level of the in-position range, changing the value of [Pr. PX14 One-touch tuning
- Overshoot permissible level] will shorten the settling time and improve the
response.