Mitsubishi Electric MR-J4 Instruction Manual page 437

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

14. USING A LINEAR SERVO MOTOR
(a) For the incremental linear encoder
By turning on the servo-on command from the controller after the power-on, the magnetic pole
detection is automatically carried out. Therefore, there is not need to set the parameter (first digit of
[Pr. PL01]) for executing the magnetic pole detection.
1) Timing chart
2) Linear servo motor movement (when FLS (Upper stroke limit) and RLS (Lower stroke limit) are
on)
Note 1. When FLS (Upper stroke limit) or RLS (Lower stroke limit) turns off during the magnetic pole detection, the operation of the
magnetic pole detection is carried on to the opposite direction. When both FLS and RLS are off, [AL. 27 Initial magnetic pole
detection error] occurs.
2. The following shows the pitch against the magnetic pole.
POINT
For the incremental linear encoder, the magnetic pole detection is required
every time the power is turned on.
Servo-on command
Base circuit
RD (Ready)
Note. The magnetic pole detection time indicates the operation time when FLS (Upper
stroke limit) and RLS (Lower stroke limit) are on.
(Magnetic pole detection start position)
RLS
(Note 1)
Linear servo motor series
Pitch against magnetic pole
[mm]
ON
OFF
95 ms
ON
OFF
ON
OFF
15 s or less
Magnetic pole detection time (Note)
Servo-on position
(Note 2)
Magnetic pole detection completion position
LM-H3
Medium thrust
LM-F
(Continuous thrust:
Less than 400 N)
48
30
14 - 16
FLS
(Note 1)
LM-U2
Large thrust
(Continuous thrust:
400 N or more)
60
LM-K2
48

Hide quick links: